Air Conditioning System Design for Data Center (2-day)
(5 - 6 November 2015, approved CPD course by CIBSE UK)
This is an advanced learning series for
data center facilities design. It targets to engineers involved in
designing or handling HVAC (Heating, Ventilation and Air Conditioning)
equipment for mission critical facilities and data center projects.
You'll be able to make informed
decisions about the best choices of cooling systems for mission critical
purposes and how system can best meet the project goal and SLA (Service
Level Agreement).
Date: 5 - 6 November 2015
Time: 10:00 - 17:30
Venue: 20/F, Office Plus, 93 - 103 Wing Lok Street, Sheung Wan, Hong Kong
(Next to Exit A2, Sheung Wan Station)
Fee: Special rate for CIBSE / HKIE all membership classes
Datacom Equipment Power Trends and Cooling Applications
-- Load trends and their application
-- Air cooling of computer equipment
-- Liquid cooling of computer equipment
-- Air cooling of computer equipment
-- Liquid cooling of computer equipment
Design Consideration
-- Design criteria
-- HVAC load
-- Computer room cooling
-- Air distribution
-- Liquid cooling
-- Availability and redundancy
-- HVAC load
-- Computer room cooling
-- Air distribution
-- Liquid cooling
-- Availability and redundancy
-- Controls
-- Integration with other MEP (Mechanical, Electrical and Plumbing) system
-- Computer Fluid Dynamics (CFD)
-- Integration with other MEP (Mechanical, Electrical and Plumbing) system
-- Computer Fluid Dynamics (CFD)
Testing and Commissioning
-- Air cleanliness test
-- Heat load test
-- Factory acceptance test
-- Site acceptance test
-- Integrated performance test (IST)
-- Heat load test
-- Factory acceptance test
-- Site acceptance test
-- Integrated performance test (IST)
Energy Efficiency
-- Power usage effectiveness
-- Chilled water plant optimization
-- Water side and air side equipment
-- Part load operation
-- Controls and energy management
-- LEED certified data center
-- Building energy code
-- Chilled water plant optimization
-- Water side and air side equipment
-- Part load operation
-- Controls and energy management
-- LEED certified data center
-- Building energy code
Sustainable Design
-- Combined heat power plant (CHP)
-- Solar cooling
-- Geothermal cooling
-- Evaporative cooling
-- Air side economizers
-- Desiccant unit
-- Solar cooling
-- Geothermal cooling
-- Evaporative cooling
-- Air side economizers
-- Desiccant unit
The learning highlights design
principles such as psychrometric chart, cooling load calculation /
estimation, etc. and the design considerations such as air distribution,
availability / redundancy, common mistakes, Computer Fluid Dynamic
(CFD) model, integration with MEPs (Mechanical, Electrical and Plumbing
system), etc.
Enrollment & Registration
Kindly complete and return an Application Form (attached) together with a crossed cheque made payable to “Strategic Media Asia Limited” - Room 403, 4th Floor, Dominion Centre, 43 - 59 Queen's Road East, Hong Kong.
About the Organizer
Strategic Media Asia Limited (SMA) is
one of the approved CPD course providers of the Chartered Institution of
Building Services Engineers (CIBSE) UK. For details, please visit www.stmedia-asia.com/about. html.
YSWong
2015年9月23日
沒有留言:
張貼留言